**Because these wells are round, the surface area available for cell attachment is dependent on the medium volume used. Corning Multiple Well Plates Single Well Only Well Approx. Total Well Working Diameter Growth Average Volume Volume Plate (Bottom) (mm) Area (cm2) Cell Yield (mL) (mL) 6-well 34.8 9.5 9.5 x 105 16.8 1.9 - 2. Description Eppendorf Cell Culture Plate, 12-well 0030 721.110: with tissue culture treated surface 0030 721.012: with non-treated surface Dimensions Plate with lid: 127.8 x 85.5 x 20.0 mm (l x w x h) Weight Plate 41 g , lid 20 g Filling volume Working volume/well: 1.0 mL/well to 2.0 mL/well Growth area 391.1 mm2/Well 6 x 10^6 cell/ml (cell suspension 3ml) I want to plate 75000 cells for each well of 6-well plate plus (2ml of media for each well). So I calculated it this way: 75000 cells/ (6 x 10^6 cell/ml)=0. Growth Area of Tissue Culture Plates and Dishes. Growth Area (cm 2) Media Volume (ml) Maximum Volume (ml) Plates. 35 mm. 8. 1.6-2.4 Useful information for various sizes of cell culture dishes and flasks. There are various sizes of dishes and flasks used for cell culture. Some useful numbers such as surface area and volumes of dissociation solutions are given below for various size culture vessels. (mL of 0.05% EDTA). Approx. volume

Plate Format 12-well Plate Color Clear Well Bottom Flat Well Bottom Color Clear Well Shape Round Cell Growth Area 1.12 cm² Recommended Medium Well Volume 1.5 mL Recommended Medium Insert Volume 0.5 mL Surface Treatment TC-Treated Sterile Yes Membrane Materia TPP® tissue culture plates 12 well plate, flat bottom, polystyrene, 3.6 cm2, sterile, 72/cs; Synonyms: 12 well plate,cell culture plate,tissue culture plate; find -Z707783 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldric

The usual media volume to surface area is .2-.5ml/cm2 The upper limit is set by gaseous diffusion through the liquid layer and the optimum will depend upon the oxygen requirement of the cells. Also more confluent cultures require more media and changing more frequently. i.e. A well in a 6-well dishe has a surface area of 9.6cm2 and you can use the half of maximum volume for washing. in 96 wells plate it would be 200 micro liter. in 48 wells:400. in 24 well: 600. in 12 well: 800. in 6 well 1 ml. it is suitable for cell. The results indicated that the area of mineral deposition was inversely proportional to the volume of medium (Fig. 1A). To verify these results, mineral deposition was investigated using a 12-well plate with 0.75, 1.0 or 1.5 ml/well 6, 12, 24, 48 and 96-Well Plates and Microplates, Corning®. These clear polystyrene plates have nonreversible lids with condensation rings to reduce contamination. Selection of 6-, 12-, 24-, 48 or 96- well plates. They feature individual alphanumerical codes for well identification

What is the lowest volume you can use in a 12 well plate

Cell culture plate, 12 well, surface: Standard, flat base Size Max. volume 6,64 ml Width of product 85,2 mm Height of product 22,5 mm Length of product 127,8 mm Material & colours Product material Polystyrene (PS) Colour of product transparent Cap material Polystyrene (PS) Purity & certification Product in accordance with MDD or IVDD no medical. 0.00. CELLLSTAR® 12 Well Cell Culture Multiwell Plates. Improved cell adhesion through physical surface treatment. Free of detectable DNase, RNase, human DNA, non-pyrogenic. Non-Cytotoxic. High clarity and low autofluorescence. Lid enables gas exchange with the lowest possible evaporation. Single position lids to prevent cross-contamination

Well Plate Reader Accessory. For measuring the fluorescence or phosphorescence from a 6-, 12-,24-, 48-, or 96-well plate in either the X or Y direction or for luminescence micro densitometry of TLC plates and electrophoresis gels. Controlled by the computer. Silica excitation fiber, glass emission fiber and inserts for each format. Surface areas used for volume calculations are 3.5 cm 2 for 12-well plates, and 1.8 cm Low for 24-well plates. Working volumes are calculated to give 5 mm growth media over the growth surface. Media volumes shown are suggestions, different volumes may be necessary depending on the cell type and experiment being. Corning® Costar® TC-Treated Multiple Well Plates size 12 wells, clear polystyrene plate, flat bottom, case of 100 (20 Bulk Packs of 5), sterile, lid; Synonyms: cell culture plate,multiwell plates,tissue culture plates,multi well plates,multiple well plates; find -CLS3512 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldric OptiMEM(in uL, equal volume for DNA and Lipofectamine) = Lipofectamine(in uL) * 25 Protocol (6 well dish) Plate cells and grow to ~70% confluence in 2 mL media without antibiotics (DMEM with 10% FBS, no PSG; use 1 mL for 12 well plate, and use half the amount of DNA DJ Hickey, et al., Colloids and Surfaces B: Biointerfaces Volume 175, 1 March.

Weight Plate 55 g, lid 20 g Filling volume Working volume/well: 0.3 mL/well to 0.5 mL/well Growth area 85.6 mm2/Well Material Polystyrol, meets USP Class VI specifications Color Transparent Operating temperature -86 °C to +60 ° Centrifugability* Can be centrifuged up to 2 500 x g. When arranged in a stack (4 plates) can be centrifuged up to. 12 mm 1.12 cm2 12 well 1.5 mL 0.5 mL 24 mm 4.67 cm2 6 well 2.6 mL 1.5 mL 75 mm 44 cm2 100 mm dish 13 mL 9.0 mL 2.An initial equilibrium period may be used to improve cell attachment by adding medium to the multiple well plate well and then to the Transwell insert. The plate should then be incubated for at least one hour or even overnight at the. Culture surface: 113.1 mm². Height (overall): 16.25 mm. Inner/outer diameter (top): 13.85 mm / 15.85 mm. Working volume ThinCert™: 0.3 ml - 1.0 ml. Working volume well: 1.0 ml - 2.0 ml. Improved cell adhesion through physical surface treatment. Sterile. Packaging: 4 Multiwell plates per box, 48 ThinCert™ inserts per box Recommended working medium, trypsin volume and cell inoculation density: Author: Long-Cheng Li Source: Date Added: Tue May 14 2002 Date Modified: Tue Apr 27 2004 Abstract: Useful data for cell subculture with different culture vessels 11. Gently add 1/2 of the final volume of culture medium to each well of the MEA. Adding the medium too quickly will dislodge the adhered neurons. Recommended well volumes for each plate type are: 6- and 12-well = 1000 µl, 24-well = 500 µl, 48-well = 300 µl, 96 well = 200 µl. 12

Growth Area of Tissue Culture Plates and Dishes The

  1. Procedure (for one 6-well plate or 12-well plate) Under the culture hood, prepare 200 mL of 1.25X DPBS: Combine 5.6 mL of 10X PBS with 194.4 mL of 1X DPBS. Under the culture hood, prepare a collagen coating solution (300 μg/mL) by combining the following into a 50-mL centrifuge tube or similar sterile container in order: 266 µL of NaOH (0.1 M.
  2. e) = Lipofecta
  3. The XBLOK2412 is an SBS-format 24-well 12mL polypropylene plate with the designed purpose of automating cell culture and genomic extractions. The XBLOK2412 has the largest capacity of any 24-well plates on the market to date (12mL, recommended max working volume of 10.5mL) and when used in tandem Related Products: 24 Deep Well Plates
  4. volumes for CellMatrix coating solution, culture media, and Accutase solution based on the surface area of the cell culture vessel as described in Table 3. 1. Preparation of CellMatrix gel-coated plates. This protocol is designed for coating a 12-well plate. Half mL of diluted CellMatrix gel is required per well of a 12-well plate
  5. Corning ™ Costar ™ Flat Bottom Cell Culture P. $574.00 / Case of 100. Catalog No. 07-200-740
  6. Our MicroWell Plates have excellent cell attachment. All styles are designed to be stackable and are radiation sterilized. 10µl Well Plates. They are Terasaki format plates measuring 56 x 82 mm and having 60 or 72 wells. Wells are shaped like inverted truncated cones, each with a working volume of 10µl

Useful Numbers for Cell Culture Thermo Fisher Scientific

  1. Plate/Dish Size Media Volume 24 well plate 12 well plate 6 well plate 60 mm dish 10 cm dish 0.25-0.5 mL 0.5-1 mL 1-2 mL 3-4 mL 8-12 mL E.g., If your desired MOI is 10,000 and you want to transduce 1,000,000 cells, you need 1010 GC. If the titer is 1x1013 GC/mL, add 1 μL of the AAV stock to the medium. Calculating the Volume of Virus Neede
  2. The #CnT-SP Spacer Plate fits on top of standard 12-well plates and solves the medium volume problem by lifting the inserts, and thus increasing medium volume without needing a special deep-well plate. Importantly, the #CnT-SP Spacer Plate is re-usable. Simply sterilize by soaking in alcohol prior to use
  3. 657 110 ThinCert™Plate, 6 well, sterile, with lid 1 50 665 110 ThinCert™Plate, 12 well, sterile, with lid 1 60 Key Facts Available as 6 well and 12 well plate Length x Width: 129.5 x 86.6 mm; Height: 39.5 mm (6 well); 31.8 mm (12 well) Volume in air-lift: 6 well: approx. 20 ml; 12 well: approx. 4 ml Deep wells for large medium volume
  4. Place exactly 1ml in one well of a 12 well plate. Add an additional 1ml of Clone Medium to the well. Can store spleen suspensions in 12 well plate overnight in refrigerator. Use remaining spleen cells for phenotype FACS if desired - wash with Staining Buffer to remove Clone Medium. Stimulation of Spleen Cells. Prepare Stimulating Medium
  5. Figure 1:RVFV plaque overlay comparisons utilizing 12 well plates. Veros were plated at 2.5 x 10 5 cells in 12 well plates and infected with 200 µl using the same serially diluted starting sample of MP12. After infection 1.5 ml overlays of 0.3% agarose,0.6% Avicel, or 1% CMC (final concentrations), were applied in order to directly compare the.
  6. 12-well 2.00 1 mL 2 × 50 μL 1 2 1.5, 3 30 3 6-well 5.00 2 mL 2 × 125 μL 2.5 5 3.75, 7.5 75 7.5 60 mm 11.05 5 mL 2 × 250 μL 5.5-11 11-22 8.25, 16.5 166 17 10 cm 28.95 10 mL 2 × 500 μL 14-28 28-56 21.7, 43.4 434 43 T75 39.47 15 mL 2 × 750 μL 20-40 40-80 29.6, 59.2 592 59 T175 92.11 35 mL 2 × 1.75 mL 46-90 92-180 69, 138.

4. Add the contents of Tube 1 to Tube 2, for a total volume of 20 μL. Mix by pipetting carefully up and down and incubate for 20 minutes at room temperature, and then add 80 μL of antibiotic-free complete medium for a total volume of 100 μL transfection medium. 5. Remove culture medium from the wells of the 96-well plate and ad Recommended cell seeding and medium volume for specific plate formats and tissue culture flasks to obtain approximately 80% confluence in 2-3 days: 1. 150 mm plates: 5 x 106/20 ml medium 2. 100 mm plates: 2 x 106/10 ml medium 3. 60 mm plates: 5 x 105/5 ml medium 4. 6-well plates: 3 x 105/well/3 ml medium 5 Pre-warm required media Pre-warm gelatin Dish/Flask/Plate Volume of Gelatin/PBS Volume of Trypsin Volume of Media 6 well plate 3ml 500µl 4.5ml 96 well plate 100µl 25µl 175µl 10cm Petri dish 8ml 1.5ml 8.5ml Things you'll need An aspirator & sterile filter-free tips/pipettes Pipette aid & plastic pipettes 3 x liquid reservoir 12 well plates need 1 ml of soln and have about 400,000 cells, 24 well plates have 0.5 ml and 200,000 cells at confluency. Procedure: Short 96 well assay: EACH condition should be done in triplicate or more. 1. DAY ONE: Trypsinize one T-25 flask and add 5 ml of complete media to trypsinized cells. Centrifuge in a steril

12 mm Transwell® with 0

TPP® tissue culture plates 12 well plate, flat bottom

Tissue-culture treated plates and strips provide uniform and compatible surfaces for animal cell attachment and growth. TC treated 96-well plates and 8-well strips are also useful in ELISA testing. Available in 6-well, 12-well, 24-well or 96-well versions as well as 8-well strips; Plates all have distinct alpha-numeric designation 2. Add the recommended volume (Table 1) to a sterile 1.5-ml microfuge tube. 3. Add the corresponding volume of virus-containing supernatant (Table 1) to the same tube and mix by gently pipetting up and down. Your virus may be resuspended in PBS or complete media. 4. Incubate the bead-virus mixture at room temperature or on ice for 20-30 min

How much media needed for cells in different cell culture

  1. e) = Lipofecta
  2. in a 37°C incubator. Then add 10 mL of growth medium and use a 10 mL serological pipette with a 200 µL tip on the end to pipette the cell suspension up and down at least 5 times
  3. media from 24-well plates. 5. After incubation time, 150ul per well of serum free media was added to the solution. It might be easier to add the 150ul of media directly to the wells of the plate rather than to each solution. 6. Add each PEI solution in a drop-wise manner to the corresponding cells. Make sure that drops are distributed over.
  4. ation. There is a tangible difference between.
  5. Well plate is a common laboratory consumables, except for 96 well plate, there are some types of microplates: 6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate, 1536 well plate. well-plates Reference. Microplate Standards Wikipedia: Microplate Microplate PD

What are ideal volumes to use for washes in 6, 24, 48, 96

How much medium do you use for cell culture? Medium volume

With wells full of media, cells can expand from as few as 125,000 per cm2 to as many as 40x106 per cm2 Fresh media is only required every 4-5 days, not on a daily or every other day schedule, as with traditional plates Media Volumes. Plate Type Cell Density per Well Approx. Media Volume (ml) 96-well 8,000-12,000 0.1 24-well 50,000-100,000 0.5 12-well 100,000-200,000 1.0 6-well 250,000-450,000 2.0 60 mm 275,000-825,000 4.0 100 mm 2 x 10 6-6 x 10 6 7.0 Option 2: Same Day Plating Maintain low passage number, healthy, log phase cell After electroporation add 0.5mL of complete RPMI media into electroporation cuvette. 8. Add entire volume of transfection cell mixture into the 12 well plate using transfer pipette. 9. Day after transfection: Spin down the cells at 500 x g for 5 min. at room temperature. Resuspend the cells in 2mL complete media and pl ace back into the 12 well. 2.11 Add ~500 µl of the pre-equilibrated culture media to the cuvette and gently transfer the sample into the 12-well plate (final volume of 2 ml media per well/sample). Use the supplied pipettes and avoid repeated aspiration of the sample 3. Post Nucleofection® 3.1 Incubate the cells in humidified 37°C/5% CO 2 incubator until analysis. Gene.

6, 12, 24, 48 and 96-Well Plates and Microplates, Corning

Product description - Sarsted

Volume of cells to add when seeding a new plate: 500 µl per well (1 ÷ 1/2) [500,000 cells per well: approximately half covered with cells after they attach] Volume trypsin to add when transferring cells: 1 ml per well (2 ÷ 1/2) Inhibitor experiments: Use 80 µl per well of the appropriate dilution. For the control, add media For small scale transductions or titering assays, cells may be plated into multiwell microtiter plates (e.g., 0.5 ml/well for 24-well plates or 1 ml/well for 12-well plates). To transduce larger numbers of cells, use larger plates and scale up the volume accordingly; To each plate, add an appropriate amount of lentivirus Order part # PDCF OS 30 (Fluid for removal of coverslips from glass bottom plates, available from MatTek). Place the cover of the multi-well plate on a clean surface top side up (Do not invert the cover). Pipette 3.0 ml of PDCF OS 30 fluid onto the top side of the cover. Place the bottom of the multi-well plate on top of the cover Media&and&stock&formulations:&! 0.1%&gelatin&(900&mL)& & • Add!0.9!g!type!A!gelatin!to!900!mL!Millipore!water!and!autoclave.! • Sterile!filter!using!0.22!μM. One should contrast this to a standard 12-well plate where cells reside in ~2.5 mm of culture media at a 300 cells/μL. Therefore, cell-to-volume ratio in low volume culture plates was over 30 times higher when compared to standard culture plates

12 well plate volume — cell culture consumables and

Clear 12 Well Plates, Single Packed - Greiner Bio-On

4.7 Transfer Matrigel mixture to the conical with cold media. Repeat until all Matrigel is added to cold media. 4.8 Using the cold serological pipette, transfer basal media/ Matrigel mixture to your TC dish(es) at the following volumes: • 6-well plates = 1ml/well • 12-well plates = .5ml/well • 24-well plates = .5ml/well plate supporting assay miniaturisation in high-throughput screening 2.1 Determining the best well geometry 2.2 Performance of the 384 Deep Well Small Volume™ plate for pre-dilutions 2.3 Use of 384 Deep Well Small Figure 12: Well Geometry of a standard V-bottom (A) well and well 6-well plates 12-well plates 10-cm dishes or T-75 flasks DAY 1 1. Trypsinize and count cells. Resuspend 3 million cells in a final volume of 6 mL. 2. Add 18 µL of 1000x polybrene (optimal concentration previously determined). 3. Add 1 mL of cell suspension to 5 wells of a 12-well plate. Add 0, 200, 400, 800, 1000 µL of Cas9 virus per well Part No. Description Stock Status Case Qty Price Purchase; 229578 : 4.6mL 48 Deep Well Storage Plate, PP, Rectangle Well, U-Bottom, Non-steril

12 Well Plate at Thomas Scientifi

Corning® Costar® TC-Treated Multiple Well Plates size 12

incubator. Depending upon the plate configuration, please use the chart below to determine medium volume to remove from each well. Cultureware Total shipping volume per well Removal volume per well 96 well plates 300 l/well 150 l 48 well plates 1.3 ml/well 0.8 ml 24 well plates 3.0 ml/well 2.0 ml 12 well plates 5.8 ml/well 3.8 ml 5 Celigo® Liquid Volume & Cell Density Recommendations Plate Type Recommended Final Volume (µl) Cell Density Range 1536 Well 8 1 - 1,536 384 Well - Low Volume 20 1 - 2,000 384 Well - High Volume 50 1 - 4,000 96 Well 175 1 - 20,000 48 Well 250 20 - 50,000 24 Well 400 50 - 100,000 12 Well 1000 50 - 200,000 6 Well 2000 50 - 1,000,000 Special note Eppendorf Cell Culture Plates are designed for expansion of smaller cell numbers and for cell-based assays. The chimney-well design avoids inhomogeneous growth of cells in the outer ring of wells which reduces costs and increases efficiency

12 well plate volume — cell culture consumables and

You will get useful cell numbers in various sizes of tissue cell culture dishes, plates and flasks. We provides useful numbers, such as, growth surface area, volumes of dissociation EDTA-Trypsin solution, culture medium, seeding density and cell numbers at 100% confluent, are given below for Greiner Bio One and Nest Biotechnology cell culture. Alvetex ® Scaffold: primarily designed for 3D culture of mammalian cells within the scaffold, forming structures up to 200µm thick. (Average void size: 42 µm). Alvetex ® Strata: is designed for growing cells in 3D on the top surface. Cells still grow in 3D but are less likely to enter the scaffold because the voids are much smaller With Millicell inserts, attachment or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell inserts make it possible to study both sides of the cell monolayer. Millicell inserts are available for 24-, 12-, or 6-well plates For seeding MM on 60 mm plates, use Table 2. Table 1 Recommended cell suspension volume per vial using a 6-well, 12-well, or 24 well format Well format Surface area/well (approx. values) Volume of media/well Volume of cell suspension from vial/well # of wells/vial 6-well 150 9.6 cm2 3.0 ml l 6 wells 12-well 60 3.9 cm2 2.0 ml l 15 wells

NOTE: This protocol has been adapted for a 12-well plate system. To adapt this protocol for your preferred system, volumes should be adjusted accordingly. Fixation of Adherent Cell Lines a) Grow cells on 18 mm round #1 coverglass in a 12-well cell culture plate. b) Aspirate growth medium, and wash with 1 mL of 1X PBS. c) Add 1 mL of fixation. Plate/Dish Size Media Volume 24 well plate 12 well plate 6 well plate 60 mm dish 10 cm dish 0.25-0.5 mL 0.5-1 mL 1-2 mL 3-4 mL 8-12 mL E.g., If your desired MOI is 10 and you want to transduce 1,000,000 cells, you will need 107 VP. If the titer is 1x1010 VP/mL, add 1 μL of the viral stock to the medium. Calculating the Volume of Virus Neede The INTEGRA Petri dish filler helps you to avoid these drawbacks. MEDIAJET can process up to 1100 dishes in a single hour and provides truly reliable walk-away operation. Equipped with a UV lamp, the filling chamber where Petri dishes are automatically filled with agar medium, is kept free from contamination. Get a quote

0.4um ThinCert™ 12 Well Cell Culture Insert

All plates (except 08-772-2A and 08-772-16) have patented labyrinth lid that reduces evaporation of media from wells, minimizes the risk of contamination; Deep skirt and serrated edge permit a firmer grip for plate manipulation; Exceptional optical clarity allows for visualization of all cell monolayer For seeding MSMa on 60 mm plates, use Table 2. Table 1 Recommended cell suspension volume per vial using a 6-well, 12-well, or 24 well format Well format Surface area/well (approx. values) Volume of media/well Volume of cell suspension from vial/well # of wells/vial 6-well 9.6 cm2 3.0 ml 150 l 6 wells 12-well 60 3.9 cm2 2.0 ml l 15 wells LyoVec™ is compatible with all cell culture media. After reconstitution, 50 µl of LyoVec™ is recommended per transfection of 1-4 x 105 cells/well in a 12-well plate. • lyec-12: 4 small vials (125 µg per vial), sufficient to perform 160 reactions The ratio volume of cells/volume of complex is an important paramete 12 well plate * Advantages: can accomodate up to 12 strains, low media usage especially if you use antibiotics, handling flexibility, minimal contamination * Disadvantages: streaking to isolate single colonies is very difficult due to small streak.. Due to the size of copper coupons (1 × 1 cm), 12-well plates were selected as a testing platform in this study. However, other plate types accommodating the surfaces of interest can also be selected

plates from each original tissue culture plate. Adjust the volume so that the cell count = 200,000 cells/ml. 4. Add 0.1 ml of cell suspension to 10 ml tubes. 5. Label the 35 mm base agar dishes appropriately (from Step 3). (If they have been stored, it is a good idea to remove the plates from 4°C about 30 minutes prior to plating to allow them t 3. Dispense the recommended volume (below) of 1X PLB into each culture vessel. Volumes of 1X PLB to Use in Step 3. Passive Lysis Active Lysis Plate Size 1X PLB Dish/Plate Size 1X PLB 6-well 500µl 100 × 200mm 1ml 12-well 250µl 60 × 15mm 400µl 24-well 100µl 35 × 12mm 200µl 48-well 65µl 6-well 250µl 96-well 20µl 12-well 100µl 4 Plate format Volume laminin:PBS per well 6 - well 1 ml 12 - well 500 ul 24 - well 500 ul 48 - well 200 ul 96 - well 100 ul • Seal the plates with parafilm, place them in a clean sealed bag and store them in fridge over night for next day experiment or for long term use. The maximum time you can keep your plates in the fridge is 3-4 weeks 1) Aspirate the media from the wells for harvesting. 2) Add high concentration trypsin (0.25%) for washing and remove immediately. For a single well of an 8-well chamber slide, use 250 μl of trypsin for washing. For cultures grown in larger wells, such as 24-well or 12-well plates, use 500 μl or 1 ml, respectively for washing

NOTE: This protocol has been adapted for a 12-well plate system. To adapt this protocol for your preferred system, volumes should be adjusted accordingly. Fixation for Simultaneous IF + FISH in Adherent Cells a) Grow cells on 18 mm round #1 coverglass in a 12-well cell culture plate. b) Aspirate growth medium, and wash with 1 mL of 1X PBS 96 Well Strip Plates › 96 Well Round Bottom Polystyrene › 96 Well Standard Volume Polypropylene › 96 8 Well Strip Plates › 12 Well Strip Plates › 16 Well Strip media - Differentiation of semi-adherent cells - Transfection - Transductio

For plates (384-, 96-, 48-, 24- and 12-well), tubes (1.5 and 2.0 mL), agarose gels and more Tip spacing freely selectable from 4.5 to 33 mm, depending on pipette variant Format limiter for quick switches backwards and forwards between source and destination format NOTE: The steps that follow assume a 100 mm plate. When using other sized plates, scaling should be done according to surface area. Refer to Table 3 for appropriate scaling of common plate sizes. Aspirate the old media with an aspirating pipette to remove the dead cells. Slowly add 10 mL of warmed 1X PBS to the cells Remove media from 15 cm. Wash cells 1x with 10 mL of PBS. Add 2.5 mL of fresh 0.05% trypsin and incubate at 37 C for 5-10 min (depending on confluency and when cells begin to detach) Dislodge cells with shear force (tap plate against hood) and harvest with 7.5 mL media. Generate a single-cell suspension by pipetting against the plate

VIAFILL: Our reagent dispenser is suitable for filling microtiter plates quickly. A peristaltic pump dispenses a defined volume into the plates via tubing cassettes. It can be combined with a plate stacker that automatically stacks the filled plates so they can be filled without supervision. VIAFLO 96/384: As well as filling plates, our. for this media and Matrigel preparation details). Aliquot the volume/# of cells you want to replate in a 1.5 mL Eppendorf and spin down at 300 g x 5 min. J. Resuspend cells in 3D Matrigel (at ~400 cells/ul) and plate in a 12 well plate. K. Incubate for 15-25 min to allow droplet to stiffen before adding CK+DCI+Y

1. Pipette the appropriate cell suspension volume to each well of the culture vessel (seeTable 2 for recommendations). Cell suspension volume/well = [required cell density × growth area (cm 2)]/cell concentration (cells/mL from Section B, Step 3) Example: For a 12-well Nunc™ plate, a single well is approximately 3.5cm 2. If the cell count is. Low volume multi-well plate for harnessing cell-secreted growth factors (GFs). Top drawing shows the concept of low volume cell cultures where hepatocytes are cultured in shallow chambers and are confined to a local volume of ∼4 μL. Bottom drawing shows placement of an insert into a 12-well plate